Argent Data Systems OpenTracker USB Manuale Utente Pagina 14

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 43
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 13
OpenTracker USB User’s Manual 12
11.4. Warm Boot vs. Cold Boot
If the unit is already powered on and operating when you click the ‘Connect’
button, the program attempts a ‘warm boot’ operation to put the device into
configuration mode. If the firmware has been corrupted, i.e. by a failed upgrade,
it may fail to enter configuration mode. You can correct this by performing a
‘cold boot’ - power the unit off and power it on again after clicking ‘Connect’.
11.5. Working Offline
If you need to edit a configuration without connecting the tracker, click the
‘Offline’ button. You will need to have a saved configuration file to work from.
11.6. Main Configuration Window
Vedere la pagina 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 42 43

Commenti su questo manuale

Nessun commento